Skip to content

update Geometry of Rich detector

Simon Neuhaus requested to merge s.neuhaus/cbmroot:mergerequestbranch into master
  • change outer dimension of RICH detector
    • change width and length of RICH
    • change mainframe
      • make shape in top view rectangular
      • make slope on front
        • reuse mainFrame3
        • change mainframe5 to trapezoid form
        • add new mainframe7 which replace some of the mainFrame2
        • cutoff shieldingbox
      • add new mainframe8 in x-direction
      • reduce some mainframes by a length of (2x) thickness from the mainframe to reduce overlapping
        • cutoff a cubic where mainframes cross each other
        • change the length of the pillars
  • Rich entrance window
    • change width of the entrance window
    • add 10cm wide and 2cm thick Aluminum flange
    • reduce size of entrance window without flange a bit
  • Rich exit window
    • add 10cm wide and 2cm thick Aluminum flange
    • change width to 569cm
    • change hight to 384cm
    • change material of exit window from kapton to Polycarbonat
    • increase thickness to 1cm
  • Add Studs to each pillar
    • 10cm x 10cm 0.2cm thick Aluminum
  • Add Connections between pillars
    • 6cm x 2.5cm 0.2cm thick Aluminum
  • Make beampipe to beampipe tunnel
    • change material to carbon
    • change radius at entrance and exit
    • change pipe thickness to 0.3cm
    • increase the length by 0.5cm
    • change and increase cutoff at middle mirror parts
    • increase hole in sensitivity plane (move subtracted Cone)
    • remove belt types 4 and 5 because of overlap with the beampipe tunnel
Edited by Eoin Clerkin