Skip to content
Snippets Groups Projects
  1. Dec 10, 2021
  2. Dec 09, 2021
  3. Dec 08, 2021
  4. Dec 07, 2021
  5. Dec 06, 2021
  6. Dec 03, 2021
    • Pierre-Alain Loizeau's avatar
      In STS unpacker, fix bug in handling of TS_MSB cycles happening at edge of MS + cleanup · 15c78e78
      Pierre-Alain Loizeau authored
      - Replace all legacy hard-coded numerical values for the TS_MSB cycle size by a constant derived in StsXyterMessage from the data format
      - Remove deprecated special cases in the handling of the TS_MSB messages which are not present anymore in the current CRI data format
      - Do not update TS_MSB and TS_MSB cycle from the MS header when the cycle happened exactly at the end of last MS
      - Recompute the TS+MSB in TS offset from the MS heder only when changing the Cycle or the TS_MSB from the same header
      - Add static method to convert Message Type into human readable string
      - Slight improve/cleanup of debug printouts and debug levels
      
      Was leading to errors and a crash in mCBM 2021 run 1588 files node8_3_0123 and node8_5_0002
      dev_2021_49
      15c78e78
  7. Dec 01, 2021
  8. Nov 30, 2021
  9. Nov 29, 2021
  10. Nov 26, 2021
  11. Nov 25, 2021
    • Cornelius Feier-Riesen's avatar
      Correct weight values for signals · cc93ce5f
      Cornelius Feier-Riesen authored and Florian Uhlig's avatar Florian Uhlig committed
      cc93ce5f
    • Mehulkumar Shiroya's avatar
      STS geometry version v21[h-i] · 4dadea0e
      Mehulkumar Shiroya authored and Florian Uhlig's avatar Florian Uhlig committed
      STS v21h: The geometry has the target positioned at -4 cm. It can be used with the beampipe 40mm diameter upstream side
      and 104mm diameter downstream side. It has a beampipe flange on the back-side of the STS wall.
      In addition, the geometry has a sensor thickness 320 um which is similar thickness of the real silicon sensors purchased from the Hamamatsu Photonics
      for the use in the real experiment.
      Furthermore,the mico-cable is defined as a single volume attached to the silicon sensors. Micro-cable thickness (320 um) is choosen and
      the material Manganese is taken based on the calculation done by taking the current microcable design, thickness and its material.
      
      STS v21i: The geometry has the target positioned at -44 cm from the center of the magnet. It can be used with the beampipe 40mm diameter upstream side
      and 104mm diameter downstream side. It doesn't have a beam-pipe flange on the back-side of the wall.
      In addition, the geometry has a sensor thickness 320 um which is similar thickness of the real silicon sensors purchased from the Hamamatsu >
      for the use in the real experiment.
      Furthermore,the mico-cable is defined as a single volume attached to the silicon sensors. Micro-cable thickness (320 um) is choosen and
      the material Manganese is taken based on the calculation done by taking the current microcable design, thickness and its material.
      4dadea0e
    • Valentina Akishina's avatar
  12. Nov 24, 2021
  13. Nov 23, 2021
Loading